1bd47de339
Apparently I simply forgot to calibrate it when the port was done and the current values are just plain wrong, especially for the charging curve. Change-Id: Ied3cafa52f31f182f953714e28edc4c5e891255f
46 lines
1.6 KiB
C
46 lines
1.6 KiB
C
/***************************************************************************
|
|
* __________ __ ___.
|
|
* Open \______ \ ____ ____ | | _\_ |__ _______ ___
|
|
* Source | _// _ \_/ ___\| |/ /| __ \ / _ \ \/ /
|
|
* Jukebox | | ( <_> ) \___| < | \_\ ( <_> > < <
|
|
* Firmware |____|_ /\____/ \___ >__|_ \|___ /\____/__/\_ \
|
|
* \/ \/ \/ \/ \/
|
|
* $Id$
|
|
*
|
|
* Copyright (C) 2012 by Amaury Pouly
|
|
*
|
|
* This program is free software; you can redistribute it and/or
|
|
* modify it under the terms of the GNU General Public License
|
|
* as published by the Free Software Foundation; either version 2
|
|
* of the License, or (at your option) any later version.
|
|
*
|
|
* This software is distributed on an "AS IS" basis, WITHOUT WARRANTY OF ANY
|
|
* KIND, either express or implied.
|
|
*
|
|
****************************************************************************/
|
|
#include "config.h"
|
|
#include "powermgmt-target.h"
|
|
|
|
const unsigned short battery_level_dangerous[BATTERY_TYPES_COUNT] =
|
|
{
|
|
3659
|
|
};
|
|
|
|
const unsigned short battery_level_shutoff[BATTERY_TYPES_COUNT] =
|
|
{
|
|
3630
|
|
};
|
|
|
|
/* voltages (millivolt) of 0%, 10%, ... 100% when charging disabled */
|
|
const unsigned short percent_to_volt_discharge[BATTERY_TYPES_COUNT][11] =
|
|
{
|
|
/* figured from discharge curve */
|
|
{ 3631, 3697, 3762, 3784, 3805, 3838, 3902, 3961, 4016, 4091, 4178 },
|
|
};
|
|
|
|
/* voltages (millivolt) of 0%, 10%, ... 100% when charging enabled */
|
|
const unsigned short percent_to_volt_charge[11] =
|
|
{
|
|
/* figured from charge curve */
|
|
3833, 3866, 3910, 3923, 3943, 3969, 4009, 4047, 4095, 4154, 4192
|
|
};
|