7d7969114d
git-svn-id: svn://svn.rockbox.org/rockbox/trunk@19748 a1c6a512-1295-4272-9138-f99709370657
59 lines
2.4 KiB
C
59 lines
2.4 KiB
C
/***************************************************************************
|
|
* __________ __ ___.
|
|
* Open \______ \ ____ ____ | | _\_ |__ _______ ___
|
|
* Source | _// _ \_/ ___\| |/ /| __ \ / _ \ \/ /
|
|
* Jukebox | | ( <_> ) \___| < | \_\ ( <_> > < <
|
|
* Firmware |____|_ /\____/ \___ >__|_ \|___ /\____/__/\_ \
|
|
* \/ \/ \/ \/ \/
|
|
* $Id$
|
|
*
|
|
* Copyright (C) 2009 by Michael Sevakis
|
|
* Copyright (C) 2008 by Bertrik Sikken
|
|
*
|
|
* This program is free software; you can redistribute it and/or
|
|
* modify it under the terms of the GNU General Public License
|
|
* as published by the Free Software Foundation; either version 2
|
|
* of the License, or (at your option) any later version.
|
|
*
|
|
* This software is distributed on an "AS IS" basis, WITHOUT WARRANTY OF ANY
|
|
* KIND, either express or implied.
|
|
*
|
|
****************************************************************************/
|
|
#ifndef POWERMGMT_TARGET_H
|
|
#define POWERMGMT_TARGET_H
|
|
|
|
#if defined(SANSA_C200)
|
|
/* This configuration triggers a single charge cycle upon plugging and stops.
|
|
* The true voltage cannot be read accurately and so monitoring isn't really
|
|
* possible. The battery filter is still synced to have a proper reading
|
|
* when disconnecting. */
|
|
#define BATT_FULL_VOLTAGE 5121 /* Won't read this high - force start */
|
|
#define BATT_VAUTO_RECHARGE 0 /* Won't read this low - force one cycle */
|
|
#define BATT_CHG_V CHG_V_4_20V
|
|
#define BATT_CHG_I CHG_I_300MA
|
|
#define CHARGER_TOTAL_TIMER (4*3600*2) /* 4 hours enough? */
|
|
#define ADC_BATTERY ADC_BVDD
|
|
#elif defined(SANSA_E200)
|
|
/* PREFERRED - Check if topped-off and monitor voltage while plugged. */
|
|
#define BATT_FULL_VOLTAGE 4160
|
|
#define BATT_VAUTO_RECHARGE 4100
|
|
#define BATT_CHG_V CHG_V_4_20V
|
|
#define BATT_CHG_I CHG_I_300MA
|
|
#define CHARGER_TOTAL_TIMER (4*3600*2) /* 4 hours enough? */
|
|
/* On e200 ADC_RTCSUP seems to represent battery voltage better than
|
|
* ADC_BVDD during charging (ADC_BVDD is way too high) and appears the
|
|
* same in normal use.
|
|
*/
|
|
#define ADC_BATTERY ADC_RTCSUP
|
|
#endif
|
|
|
|
void powermgmt_init_target(void);
|
|
void charging_algorithm_step(void);
|
|
void charging_algorithm_close(void);
|
|
|
|
/* We want to be able to reset the averaging filter */
|
|
#define HAVE_RESET_BATTERY_FILTER
|
|
|
|
#define BATT_AVE_SAMPLES 32
|
|
|
|