Commit graph

4 commits

Author SHA1 Message Date
Szymon Dziok
228c47be4c Samsung YH-925: Don't add anything to adc value while reading it.
OF doesn't do such thing. Values in mV are converted proportionally, so no change
 to the battery meter.

Change-Id: Ic545b0514535e7f17f0379ed02f6bdf515f69ac6
2014-07-28 22:11:33 +02:00
Szymon Dziok
f74edac8c7 Samsung YH-920: Proper values for battery monitoring, based on the OF formula.
Change-Id: I894eb6bad600bd059fe9a5ea1103737a736d4005
2014-07-28 22:11:33 +02:00
Sebastian Leonhardt
7e778c5f49 Samsung YH-820: enable battery monitoring
The "percent_to_volt_charge" values are quite arbitrary
and may need some more tweaking.

Change-Id: I9f177d46681030d615fe2c2e78cf9bd2dde026af
Reviewed-on: http://gerrit.rockbox.org/824
Reviewed-by: Szymon Dziok <b0hoon@o2.pl>
Tested: Szymon Dziok <b0hoon@o2.pl>
2014-07-27 12:09:36 +02:00
Rafaël Carré
5cf79723ec move PP specific files to pp/
git-svn-id: svn://svn.rockbox.org/rockbox/trunk@31533 a1c6a512-1295-4272-9138-f99709370657
2012-01-03 04:39:56 +00:00
Renamed from firmware/target/arm/adc-pp5020.c (Browse further)