* __________ __ ___.
* Open \______ \ ____ ____ | | _\_ |__ _______ ___
* Source | _// _ \_/ ___\| |/ /| __ \ / _ \ \/ /
* Jukebox | | ( <_> ) \___| < | \_\ ( <_> > < <
* Firmware |____|_ /\____/ \___ >__|_ \|___ /\____/__/\_ \
* \/ \/ \/ \/ \/
* $Id$
*
* Copyright (C) 2002 by Heikki Hannikainen, Uwe Freese
* Revisions copyright (C) 2005 by Gerald Van Baren
*
* All files in this archive are subject to the GNU General Public License.
* See the file COPYING in the source tree root for full license agreement.
*
* This software is distributed on an "AS IS" basis, WITHOUT WARRANTY OF ANY
* KIND, either express or implied.
*
****************************************************************************/
#include "config.h"
#include "adc.h"
#include "powermgmt.h"
const unsigned short battery_level_dangerous[BATTERY_TYPES_COUNT] =
{
2800
};
const unsigned short battery_level_shutoff[BATTERY_TYPES_COUNT] =
{
2580
};
/* voltages (millivolt) of 0%, 10%, ... 100% when charging disabled */
const unsigned short percent_to_volt_discharge[BATTERY_TYPES_COUNT][11] =
{
/* measured values */
{ 2600, 2850, 2950, 3030, 3110, 3200, 3300, 3450, 3600, 3800, 4000 }
};
/* voltages (millivolt) of 0%, 10%, ... 100% when charging enabled */
const unsigned short percent_to_volt_charge[11] =
{
/* TODO: This is identical to the discharge curve.
* Calibrate charging curve using a battery_bench log. */
2600, 2850, 2950, 3030, 3110, 3200, 3300, 3450, 3600, 3800, 4000
};
/* Battery scale factor (guessed, seems to be 1,25 * value from recorder) */
#define BATTERY_SCALE_FACTOR 8275
/* full-scale ADC readout (2^10) in millivolt */
/* Returns battery voltage from ADC [millivolts] */
unsigned int battery_adc_voltage(void)
{