rockbox/firmware/target/arm/sandisk/sansa-e200/powermgmt-e200.c
Andree Buschmann 5ead6a6056 Submit FS#11926, calibrate charge curve for e200v1. Thanks to Martin Ritter.
git-svn-id: svn://svn.rockbox.org/rockbox/trunk@29282 a1c6a512-1295-4272-9138-f99709370657
2011-02-11 15:58:39 +00:00

48 lines
1.7 KiB
C

/***************************************************************************
* __________ __ ___.
* Open \______ \ ____ ____ | | _\_ |__ _______ ___
* Source | _// _ \_/ ___\| |/ /| __ \ / _ \ \/ /
* Jukebox | | ( <_> ) \___| < | \_\ ( <_> > < <
* Firmware |____|_ /\____/ \___ >__|_ \|___ /\____/__/\_ \
* \/ \/ \/ \/ \/
* $Id$
*
* Copyright (C) 2002 by Heikki Hannikainen, Uwe Freese
* Revisions copyright (C) 2005 by Gerald Van Baren
*
* This program is free software; you can redistribute it and/or
* modify it under the terms of the GNU General Public License
* as published by the Free Software Foundation; either version 2
* of the License, or (at your option) any later version.
*
* This software is distributed on an "AS IS" basis, WITHOUT WARRANTY OF ANY
* KIND, either express or implied.
*
****************************************************************************/
#include "config.h"
#include "powermgmt.h"
const unsigned short battery_level_dangerous[BATTERY_TYPES_COUNT] =
{
3400
};
const unsigned short battery_level_shutoff[BATTERY_TYPES_COUNT] =
{
3300
};
/* voltages (millivolt) of 0%, 10%, ... 100% when charging disabled */
const unsigned short percent_to_volt_discharge[BATTERY_TYPES_COUNT][11] =
{
/* Sansa Li Ion 750mAH, took from battery benchs */
{ 3300, 3680, 3740, 3760, 3780, 3810, 3870, 3930, 3970, 4070, 4160 },
};
/* voltages (millivolt) of 0%, 10%, ... 100% when charging enabled */
const unsigned short percent_to_volt_charge[11] =
{
/* Sansa Li Ion 750mAH */
3700, 3900, 3950, 3985, 4030, 4095, 4150, 4173, 4185, 4195, 4200
};