#include "config.h"
/* The battery manufacturer's website shows discharge curves down to 3.0V,
so 'dangerous' and 'shutoff' levels of 3.4V and 3.3V should be safe.
*/
const unsigned short battery_level_dangerous[BATTERY_TYPES_COUNT] =
{
3400
};
const unsigned short battery_level_shutoff[BATTERY_TYPES_COUNT] =
{
3300
};
/* voltages (millivolt) of 0%, 10%, ... 100% when charging disabled */
const unsigned short percent_to_volt_discharge[BATTERY_TYPES_COUNT][11] =
{
{ 3300, 3653, 3701, 3735, 3768, 3790, 3833, 3900, 3966, 4056, 4140 }
};
#if CONFIG_CHARGING
/* voltages (millivolt) of 0%, 10%, ... 100% when charging enabled */
const unsigned short percent_to_volt_charge[11] =
{
3333, 3757, 3815, 3845, 3867, 3900, 3950, 4008, 4078, 4166, 4167
};
#endif /* CONFIG_CHARGING */